Frequency | 50-60 Hz |
---|---|
EMC | EN55011, EN 55022/B, FCC47 Part 15, EN61000-3-2, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, EN60601-1-2 |
Output tolerance (%) | ± 2% |
OPERATING TEMPERATURE | 0°C - 40°C |
STORAGE TEMPERATURE | -40°C - 70°C |
Humidity (%) | 5% to 95% non condensing |
Standards | IEC/EN/UL 60950 |
MTBF | 200.000 hours |
Leakage current (μA) | Low leakage |
Standby loss | Low standby power ≤ 0.3 watt |
Short Circuit Protection | Continuously short circuit proof |
Output Connector | FRIWO Universal output plug system |
IP class | Indoor use only |
ON diode | 0 |
CeC Energy | V |
Protection class | Class ll |
Medical Approved | 0 |
MPP 6 Watt
Product number:
7081
7081
MPP 6 Watt
–
More about the product
.